Home / Product / Medium Voltage Power Cable / MV 1x400mm² XLPE/CWS/CTS/PVC/AWA/PVC Power Cable
Medium Voltage 1x400mm2 Xlpe/cws/cts/pvc/awa/pvc Power Cable
Attribute |
Detail |
Model Number |
YJLV32 |
Brand Name |
JYXL |
Type |
Medium Voltage |
Application |
Power Station |
Conductor Material |
Aluminum |
Insulation Material |
XLPE |
Jacket |
PVC |
Voltage |
12/20KV, 18/30KV |
Cores |
single core or three cores |
Cross-section |
50-1200mm$^2$ or 50-400mm$^2$ |
Armour |
steel wire armour, steel tape armour, aluminum wire armour |
Standard |
IEC60502 |
Certificate |
CE, UL, KEMA, TUV |
Place of Origin |
Henan, China |
Packaging and Delivery
Attribute |
Detail |
Selling Units |
Single item |
Packaging Details |
Standard export drum or as your request |
Port of dispatch |
Tianjin port, Qingdao port, Shanghai port |
Supply Capacity
Attribute |
Detail |
Supply Ability |
500 kilometers per Month |
medium voltage 1x400mm2 xlpe/cws/cts/pvc/awa/pvc power cable
It is manufacture under GB/T12706-2002 standard(The same as IEC60502).
It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.
1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV.
2. 2. No. of core: Single-core, Three-core.
3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250.
4. D.C Resistance of the conductor complies with the stipulations of GB/T3956-1997.
5. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit. The Min. Bending radius of three-core cable should be no smaller than 12 times of cable outer diameter.
7. Working Frequency Voltage Test:.
For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture.
For cable with Uo of 3.6kv~18kV: 3.5Uo/5min without puncture.
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture.
NYY cable, also known as PVC-insulated power cable, is designed for power transm
4C 50mm2 U1000 RO2V Xlpe Insulation PVC/LSZH Sheathed Power Cable
XLPE Insulated Cable N2XSY NA2XSY 6 KV 10KV 20KV 35 KV Underground Power Cable
6/10Kv 120Mm2 150Mm2 185Mm2 N2xsy / Na2xsy Cable