Home / Product / Medium Voltage Power Cable / Medium Voltage 1x400mm² AWA Power Cable
Medium Voltage 1x400mm2 Xlpe/cws/cts/pvc/awa/pvc Power Cable
Attribute |
Detail |
Model Number |
YJLV32 |
Brand Name |
JYXL |
Type |
Medium Voltage |
Application |
Power Station |
Conductor Material |
Aluminum |
Insulation Material |
XLPE |
Insulation |
XLPE |
Jacket |
PVC |
Armour |
steel wire armour, steel tape armour, aluminum wire armour |
Voltage |
12/20KV, 18/30KV |
Cores |
single core or three cores |
Cross-section |
50-1200mm², or 50-400mm² |
Standard |
IEC60502 |
Certificate |
CE, UL, KEMA, TUV |
Place of Origin |
Henan, China |
Packaging and Delivery
Attribute |
Detail |
Selling Units |
Single item |
Packaging Details |
Standard export drum or as your request |
Port of dispatch |
Tianjin port, Qingdao port, Shang hai port |
Supply Capacity
Attribute |
Detail |
Supply Ability |
500 kilometers per Month |
It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.
1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV.
2. 2. No. of core: Single-core, Three-core.
3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250.
4. D.C Resistance of the conductor complies with the stipulations of GB/T3956-1997.
5. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit. The Min. Bending radius of three-core cable should be no smaller than 12 times of cable outer diameter.
7. Working Frequency Voltage Test:.
For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture.
For cable with Uo of 3.6kv~18kV: 3.5Uo/5min without puncture.
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable
NYY cable, also known as PVC-insulated power cable, is designed for power transm
12/20KV NA2XSEY 120 150 185mm2 ALUMINUM Cable XLPE Insulated Single Core Medium
63KV 69KV 90KV 110KV 230KV 225KV 345KV EHV HV MV CABLE XLPE Power Cable 1*1200MM
NA2XS(f)2Y 6/10KV 12/20KV 120 150 185 240 300MM2 Single Conductor Xlpe Insulated