Home / Product / Aerial Bundle Cable / 185mm² XLPE ACSR/AW-OC Overhead Cable (36KV Single Core)
36KV Single Core 185mm2 ACSR /AW-OC Xlpe Insulated Overhead Cable
Industry-specific attributes |
|
Insulation Material |
XLPE |
Application |
Construction |
Conductor Material |
Aluminum |
Jacket |
NONE |
Other attributes |
|
Place of Origin |
Henan, China |
Brand Name |
JYXL |
Model Number |
ABC cable |
Type |
Medium Voltage |
Product name |
11KV ACSR /AW-OC 95Sq |
Standard |
IEC 60502 |
Rated voltage |
11KV |
Conductor Material |
ACSR /AW-OC |
Conductor screen |
Extruded semi-conductive layer |
Insulation |
XLPE |
Sheathed |
HDPE |
Package |
Wooden drum |
Packaging and delivery |
|
Packaging Details |
Standard export drum |
Port of dispatch |
Tianjin port, Qingdao port, Shanghai port |
Selling Units |
Single item |
Supply capacity |
|
Supply Ability |
500 kilometers per Month |
36KV single core 185mm2 ACSR /AW-OC xlpe insulated overhead cable
1. Application: Aerial bundled cables are mainly used for secondary overhead lines on poles or as feeders to residential premises.
2. Standards: Basic design to IEC 60502 / AS/NZS 3599-1 standards.
3. Approvals
4. Construction
Phase Conductor: Circular compacted stranded H68 aluminium to BS2627.
Conductor Screen: Extruded semi-conductive layer.
Insulation: XLPE.
Insulation Screen: Extruded semi-conductive layer.
metallic Screen(optional): Copper wire screen or copper tape screen.
Separator: Semi-conductive swellable tape.
Outer Sheath: HDPE.
Support Conductor: Galvanized steel wires.
Assembly: Three XLPE insulated screened cores are bundled around the galvanized steel wires in a right hand lay.
6. Printing:
7. Construction Parameters
IEC 60502 6.35/11 kV ABC for Overhead Distribution Lines
Number of Cores x Nominal Cross Section |
Phase Conductor |
Messenger Suspension Unit |
Continuous current rating at 300C ambient temp |
||||
Stranding |
Nominal Sectional Area |
Maximum Conductor Resistance |
Stranding |
Nominal Sectional Area |
Breaking Load |
||
No.×mm^2 |
No.×mm |
mm^2 |
Ω/Km |
No.×mm |
mm^2 |
KN |
A |
3X50 + 1X25 |
19/1.78 |
50 |
0.641 |
7/3.0 |
50 |
60 |
116 |
3X70 + 1X50 |
19/.14 |
70 |
0.443 |
7/3.15 |
50 |
62 |
210 |
3X95+ 1X50 |
19/2.52 |
95 |
0.32 |
7/3.0 |
50 |
60 |
173 |
3X185+1X120 |
37/2.52 |
185 |
0.164 |
7/4.67 |
120 |
150 |
259 |
3X150 +1X50 |
37/2.25 |
150 |
0.206 |
7/3.15 |
50 |
62 |
365 |
3X240 +1X50 |
61/2.25 |
240 |
0.125 |
7/3.15 |
50 |
62 |
500 |
IEC 60502 19/33 kV ABC for Overhead Distribution Lines
Number of Cores x Nominal Cross Section |
Phase Conductor |
Messenger Suspension Unit |
Continuous current rating at 300C ambient temp |
||||
Stranding |
Nominal Sectional Area |
Maximum Conductor Resistance |
Stranding |
Nominal Sectional Area |
Breaking Load |
||
No.×mm^2 |
No.×mm |
mm^2 |
Ω/Km |
No.×mm |
mm^2 |
KN |
A |
3X50 + 1X50 |
19/1.78 |
50 |
0.641 |
7/3.0 |
50 |
60 |
165 |
3X150+ 1X50 |
37/2.25 |
150 |
0.206 |
7/3.0 |
50 |
60 |
315 |
3X185+1X70 |
37/2.52 |
185 |
0.164 |
7/3.57 |
70 |
91 |
355 |
3X70 +1X50 |
19/2.14 |
7 |
0.443 |
7/3.15 |
50 |
62 |
250 |
3X150 +1X50 |
37/2.25 |
150 |
0.206 |
7/3.15 |
50 |
62 |
370 |