Home / Product / Medium Voltage Power Cable / MV 11KV XLPE Power Cable
11KV XLPE Cable 120mm 185mm 240mm 400mm Power Cable
Key Attributes:
|
Attribute |
Value |
Category |
|
Model Number |
YJV32 |
Identification |
|
Type |
Medium Voltage (and Low Voltage) |
Voltage Class |
|
Rated Voltage |
$\mathbf{1\text{kV}-35\text{kV}}$ (Covers both Low and Medium) |
Electrical Rating |
|
Voltage (Specific Examples) |
$5\text{kV}, 11\text{kV}, 15\text{kV}, 20\text{kV}, 25\text{kV}, 33\text{kV}$ |
Electrical Rating |
|
Standard |
IEC60502 |
Compliance |
|
Conductor Material |
Copper |
Core Material |
|
Insulation Material |
XLPE (Cross-linked polyethylene) |
Dielectric |
|
Armour |
SWA (Steel Wire Armoured), STA (Steel Tape Armoured) |
Protection |
|
Jacket |
PVC (Polyvinyl chloride) |
Outer Sheath |
|
Cores |
$\mathbf{1}, \mathbf{3}$ |
Core Count/Configuration |
|
Cross Section |
$10\text{mm}^2 - 240\text{mm}^2$ |
Size Range |
|
Color(Jacket/Insulation) |
red, blue, black and so on |
Customization |
|
Application |
Construction |
Function |
|
Certificate |
$\text{CE, TUV, BV}$ |
Compliance |
|
Brand Name |
JYXL |
Logistics |
|
Place of Origin |
Henan, China |
Logistics |
|
Price |
Direct factory price |
Commercial |
Packaging and Supply Details
|
Attribute |
Value |
Category |
|
Selling Units |
Single item |
Commercial |
|
Packaging Details |
Standard export drum for $400\text{mm}$ power cable or as your request |
Packaging Style |
|
Port of Dispatch |
Tianjin port, Qingdao port or other main port |
Logistics |
This product is manufactured according to GB/T12706.1, equivalent to IEC60502.1. Or BS, DIN, ICEA
standard as customer request.
The product is suitable for power transmission and distribution lines with rated power frequency voltage up to and including 0.6/1KV.
Operating Performance
1). Rated power frequency voltage Uo/U: 0.6/1KV.
2). Max. Permissible continuous operating temperature of conductor: 90℃
3). Max. Short-circuit temperature of the conductor shall not exceed: (5S maximum duration) 250℃
4). The ambient temperature under installation should not below 0℃
5). The bending radius of a cable should not be less than 15 times of the cable diameter.
6). The test voltage (A.C.): 3.5kV/5min.
7). The flame-retardant properties of cable comply with grade A, B, C of GB/T19666-2005 or IEC60332.
|
Type |
Designation |
|
|
YJV |
Copper conductor,XLPE insulated,PVC sheathed power cable |
|
|
YJLV |
Aluminum conductor,XLPE insulated,PVC sheathed power cable |
|
|
YJY |
Copper conductor, XLPE insulated,PE sheathed power cable |
|
|
YJLY |
Aluminum conductor, XLPE insulated,PE sheathed power cable |
|
|
YJV22 |
Copper conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable |
|
|
YJLV22 |
Aluminum conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable |
|
|
YJV23 |
Copper conductor,XLPE insulated,steel tape armoured,PE sheathed power cable |
|
|
YJLV23 |
Aluminum conductor,XLPE insulated,steel tape armoured,PE sheathed power cable |
|
|
YJV32 |
Copper conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable |
|
|
YJLV32 |
Aluminum conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable |
|
|
YJV33 |
Copper conductor,XLPE insulated,steel wire armoured,PE sheathed power cable |
|
|
YJLV33 |
Aluminum conductor,XLPE insulated,steel wire armoured,PE sheathed power cable |
NYY cable, also known as PVC-insulated power cable, is designed for power transm
12/20KV NA2XSEY 120 150 185mm2 ALUMINUM Cable XLPE Insulated Single Core Medium
12/20KV NA2XSEY 120 150 185mm2 ALUMINUM Cable XLPE Insulated Single Core Medium
66KV 69kv 110kv 132KV 220KV 275KV 330KV 500KV HV MV EHV CABLE XLPE INSULATION Hi