+86 13938808058 sales@jianyuncable.com
Blog
Blog

Keep up to date with our latest company news and relevant industry knowledge.

Home / Blog >Comprehensive Guide to NYY Cable

Comprehensive Guide to NYY Cable

Time: 2025-05-05 03:56:00 Source: Henan Province Jianyun Cable Co., Ltd.


Introduction

The NYY cable is a type of power and control cable designed for fixed installations. It features a PVC-insulated and sheathed construction, making it suitable for indoor, outdoor, underground, and in concrete installations where mechanical protection is not required. NYY cables are widely used in energy distribution networks, industrial plants, and building installations.

NYY Cable

Construction

  • Conductor: Solid (Class 1) or stranded (Class 2) bare copper conductor as per IEC 60228.
  • Insulation: PVC (Polyvinyl Chloride) compound type DIV4 according to HD 603 S1.
  • Filler: PVC filler for circular shape and stability.
  • Sheath: PVC outer sheath, typically black in color, providing protection against environmental factors.
  • Core Identification:
    • NYY-J: Includes a green/yellow earth conductor.
    • NYY-O: Without green/yellow earth conductor.

Technical Specifications

  • Rated Voltage: 0.6/1 kV
  • Test Voltage: 4 kV
  • Temperature Range:
    • During Operation: -15°C to +70°C
    • During Installation: -5°C to +50°C
  • Minimum Bending Radius: 15 times the overall cable diameter
  • Flame Retardant: According to IEC 60332-1-2

Applications

NYY cables are suitable for:

  • Power distribution in industrial and residential buildings
  • Installation in ducts, underground, and in concrete
  • Outdoor installations where mechanical protection is not required
  • Fixed installations in dry, moist, and wet environments

Standards and Certifications

  • IEC 60502-1
  • VDE 0276-603
  • HD 603 S1
  • DIN VDE 0293-308
  • CE Marking
  • RoHS Compliant

Technical Data Table

Cross Section (mm²) Conductor Type Outer Diameter (mm) Approx. Weight (kg/km) Current Capacity in Air (A) Current Capacity Underground (A)
1.5 Solid 8.0 110 19 23
2.5 Solid 9.0 140 26 31
4 Stranded 10.5 180 34 41
6 Stranded 11.5 220 44 53
10 Stranded 13.5 320 61 74
16 Stranded 15.5 450 82 99
25 Stranded 18.0 620 108 130
35 Stranded 20.0 780 135 162
50 Stranded 23.0 1000 165 198
70 Stranded 26.0 1300 210 252
95 Stranded 29.0 1600 250 300
120 Stranded 32.0 1900 285 342
150 Stranded 35.0 2300 320 384
185 Stranded 38.0 2700 355 426
240 Stranded 42.0 3300 405 486

Conclusion

The NYY cable is a versatile and robust solution for fixed power and control installations. Its PVC insulation and sheath provide excellent protection against environmental factors, making it suitable for a wide range of applications in various environments. Compliance with international standards ensures safety and reliability in its performance.